Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The blower motor is inoperative in all speed positions. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the blower motor operate in any speed position? | Go to Blower Motor Malfunction | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 6 |
4 | Connect a test lamp between the blower motor supply voltage circuit and the blower motor ground circuit. Does the test lamp illuminate? | Go to Step 14 | Go to Step 5 |
5 | Test the ground circuit of the blower motor resistor assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 15 |
6 | Turn the ignition ON and OFF. Does the blower motor relay turn ON and OFF? | Go to Step 7 | Go to Step 11 |
7 |
Does the test lamp illuminate? | Go to Step 15 | Go to Step 8 |
8 |
Does the test lamp illuminate? | Go to Step 16 | Go to Step 9 |
9 | Test the battery positive voltage circuit of the HVAC control module for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 10 |
10 | Test the battery positive voltage circuit of the blower motor relay for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 13 |
11 |
Does the test lamp illuminate? | Go to Step 13 | Go to Step 12 |
12 | Test the ignition 3 voltage circuit of the blower motor relay for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 17 |
13 | Inspect for poor connections at the harness connector of the blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 18 |
14 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 19 |
15 | Inspect for poor connections at the harness connector of the blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 20 |
16 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 21 |
17 | Repair the ground circuit of the blower motor relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 22 | -- |
18 | Replace the blower motor relay. Did you complete the replacement? | Go to Step 22 | -- |
19 | Replace the blower motor. Refer to Blower Motor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 22 | -- |
20 | Replace the blower motor resistor assembly. Refer to Blower Motor Resistor Assembly Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 22 | -- |
21 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 22 | -- |
22 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |