Removal Procedure
- Remove the IP trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in Instrument Panel, Gauges and Console.
- Remove the mode door actuator.
- Remove the air distribution
case cover retaining screws.
- Remove the air distribution case cover.
- Remove and discard the air distribution case seal.
- Remove the mode door.
Installation Procedure
- Install the mode door.
- Install a new air distribution case seal.
- Install the air distribution case cover.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the air
distribution case cover retaining screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Install the mode door actuator.
- Install the IP trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in Instrument Panel, Gauges and
Console.