Table 1: | BCM Scan Tool Data List |
Table 2: | LDCM Scan Tool Data List |
Table 3: | SCM Scan Tool Data List |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition On and Engine Off / Doors, Hatch or Trunk, and Hood Closed / No Switches On / Vehicle in Park or Neutral | |||
Ignition 1 | Input Data 1 | On/Off | On |
Ignition 2 | Input Data 1 | On/Off | On |
Ignition 3 | Input Data 1 | On/Off | On |
Key In Ignition | Input Data 1 | Active/Inactive | Active |
Key Out of Ignition | Input Data 1 | Active/Inactive | Inactive |
Current Power Mode | Input Data 1 | Power Mode | Run |
Driver Door Ajar Switch | Input Data 2 | Open/Closed | Closed |
Passenger Door Ajar Switch | Input Data 2 | Open/Closed | Closed |
Column Lock State | Input Data 2 | Current State | Ignition On Unlocked |
Column Feedback | Input Data 2 | Active/Inactive | Active |
Column Lock/Unlock A | Input Data 2 | Active/Inactive | Inactive |
Column Lock/Unlock B | Input Data 2 | Active/Inactive | Inactive |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition On and Engine Off / Doors, Hatch or Trunk, and Hood Closed / No Switches On / Vehicle in Park or Neutral | |||
Door Ajar | Inputs | Closed/Ajar | Closed |
Memory 1 Select Switch | Inputs | Active/Inactive | Inactive |
Memory 2 Select Switch | Inputs | Active/Inactive | Inactive |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition On and Engine Off / Doors, Hatch or Trunk, and Hood Closed / No Switches On / Vehicle in Park or Neutral | |||
Column Position Feedback | Column Info | Volts | 0-5 Volts |
Colunm In/Out Switch | Column Info | Active/Inactive | Inactive |
Column In/Out Motor | Column Info | Active/Inactive | Inactive |
Column Out Motor Stop | Column Info | Volts | 0-5 Volts |
Column In Motor Stop | Column Info | Volts | 0-5 Volts |
Memory 1 Stored Position | Column Info | Volts | 0-5 Volts |
Memory 2 Stored Position | Column Info | Volts | 0-5 Volts |
Memory 3 Stored Position | Column Info | Volts | 0-5 Volts |