Step | Action | Value(s) | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DEFINITION: Noise originating from the blower motor and/or the air delivery system. No loss of battery or ground is occuring in the blower motor circuit. The blower motor control module and the blower motor are not exhibiting any intermittent internal shorts. For electrical diagnosis of the blower motor circuit, refer to Blower Motor Inoperative at Any Speed . | ||||||||||||||||
1 | Were you sent here from the HVAC System Check? | -- | Go to HVAC System Check | |||||||||||||
2 |
Is a scrape or pop noise evident when selecting modes or temperature settings (moving a mode or temperature valve)? | -- | ||||||||||||||
3 | Is a tick/click, chirping, groaning or scraping noise present -- constantly but decreases as blower motor speed is decreased, or only at start-up/intermttent -- in all modes? | -- | ||||||||||||||
4 | Is an air rush/whistle noise evident in all modes but not all temperature settings? | -- | ||||||||||||||
5 | Is an air rush/whistle noise evident only in defrost or lower mode? | -- | ||||||||||||||
6 |
Caution: To help avoid personal injury, use care when working around the blower motor. Blower motor case contact with any ground may start the fan or increase the fan speed. Check for blower motor and impeller assembly excessive vibration at each blower motor speed by feeling the blower case. Is excessive vibration present? | -- | ||||||||||||||
7 |
Refer to Blower Motor and Fan Replacement .
Does the blower motor impeller exhibit any of these abnormal conditions? | -- | ||||||||||||||
8 |
Refer to Blower Motor and Fan Replacement . Is the action complete? | -- | -- | |||||||||||||
9 |
Refer to Blower Motor and Fan Replacement . Was foreign material found? | -- | ||||||||||||||
10 |
Refer to Blower Motor and Fan Replacement . Is the repair complete? | -- | -- | |||||||||||||
11 |
Is the action complete? | -- | -- | |||||||||||||
12 |
Refer to Instrument Panel Upper Trim Pad Replacement in Instrument Panel, Gauges and Console. Is the action complete? | -- | -- | |||||||||||||
13 |
Refer to Instrument Panel Upper Trim Pad Replacement in Instrument Panel, Gauges and Console. Is the action complete? | -- | -- | |||||||||||||
14 |
Refer to Instrument Panel Upper Trim Pad Replacement in Instrument Panel, Gauges and Console. Is the action complete? | -- | -- | |||||||||||||
15 |
Refer to Instrument Panel Upper Trim Pad Replacement in Instrument Panel, Gauges and Console. Is the action complete? | -- | -- | |||||||||||||
16 |
Is the noise still present? | -- | Go to HVAC System Check | |||||||||||||
17 |
Is the noise still present? | -- | Go to HVAC System Check |