Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent here from the HVAC System Check (CJ2)? | -- | Go to HVAC System Check | |
2 | Remove HVACCON fuse #27, and HVAC fuse #18, in the instrument panel electrical center. Is the blower motor on? | -- | ||
3 | Replace the blower motor control module. Refer to Blower Motor Control Module Replacement . Is the repair complete? | -- | Go to HVAC System Check | -- |