Blower Motor Runs High Speed Only <<CJ2>>
Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Blower motor is always operating in the HIGH
speed mode.
|
1
| Were you sent here from the HVAC
System Check (CJ2)?
| --
|
Go to Step 2
| Go to
HVAC System Check
|
2
|
- Turn the ignition switch to the ON position.
- Depress the mode control button until the UPPER position is displayed.
- Depress the blower speed control button until the fan speed is
in the low position (one bar).
- Disconnect the blower motor connector.
- Connect the DMM between terminals A and B of the blower motor
connector.
- Measure the available voltage between terminals A and B of the
blower connector.
Is the measured voltage less than 6 volts?
| --
|
Go to Step 3
|
Go to Step 5
|
3
|
- Reconnect the blower motor connector.
- Ignition switch in the ON position.
- Mode control button in the UPPER position.
- Fan speed is in the low position (one bar).
Is the blower motor running at high speed?
| --
|
Go to Step 4
| System OK)
|
4
| Replace the blower motor. Refer to
Blower Motor and Fan Replacement
.
Is the repair complete?
| --
| Go to
HVAC System Check
| --
|
5
|
- Connect a DMM between terminal C of the blower motor control module
connector and ground.
- Measure the available voltage at terminal C of the blower motor
control module connector.
Is the voltage within the specified values?
| 4.0-5.0V
|
Go to Step 6
|
Go to Step 7
|
6
| Replace the blower motor control module. Refer to
Blower Motor Control Module Replacement
.
Is the repair complete?
| --
| Go to
HVAC System Check
| --
|
7
| Replace the HVAC Control Assembly. Refer to
Control Assembly Replacement
.
Is the repair complete?
| --
| Go to
HVAC System Check
| --
|