Removal Procedure
Caution: When you are carrying an undeployed inflator module:
• | Do not carry the inflator module by the wires or connector on
the inflator module |
• | Make sure the bag opening points away from you |
When you are storing an undeployed inflator module, make sure the bag
opening points away from the surface on which the inflator module rests.
When you are storing a steering column, do not rest the column with the bag
opening facing down and the column vertical. Provide free space for the
air bag to expand in case of an accidental deployment. Otherwise, personal
injury may result.
- Disable the SIR system. Refer to
Disabling the SIR System
.
- Remove the IP upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in Instrument Panel, Gauges and
Console.
- Remove the connector position assurance (CPA) from the inflatable
restraint IP module harness connector.
- Disconnect the inflatable
restraint IP module pigtail connector.
- Remove the inflatable
restraint IP module mounting fasteners (3).
- Remove the inflatable restraint IP module (1) from the bracket
(2).
- Fully deploy the module before disposal. If the module was replaced
under warranty, fully deploy and dispose of the module after the required
retention period. Refer to
Inflator Module Handling, Shipping, and Scrapping
.
Installation Procedure
- Install the inflatable
restraint IP module (1) to the bracket (2).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the inflatable restraint IP module mounting fasteners (3).
Tighten
Tighten fasteners to 10 N·m (89 lb in).
- Connect the inflatable
restraint IP module pigtail connector.
- Install the connector
position assurance (CPA) to the inflatable restraint IP module harness connector.
- Install the IP upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in Instrument Panel, Gauges and
Console.
- Enable the SIR system. Refer to
Enabling the SIR System
.