Removal Procedure
- Disable the SIR system. Refer to
SIR Disabling and Enabling
and
SIR Disabling and Enabling
in SIR.
- Remove the instrument panel (I/P) cluster trim plate from the I/P carrier.
Refer to
Instrument Cluster Trim Panel Replacement
in Instrument Panel, Gages, and Console.
- Disconnect the electrical connector from the hazard warning switch if
required.
- Disconnect the electrical connector from the dimmer switch (2).
- With a small flat-bladed tool release the retaining tabs (1) for
the dimmer switch (2).
- From the front of the I/P cluster trim plate, push outward on the dimmer
switch (2).
This will remove the dimmer switch (2) from the I/P cluster trim plate.
Installation Procedure
- Align the dimmer switch (2) with the opening in the I/P cluster trim
plate.
- Push inward on the dimmer switch (2) until the switch is fully
seated into the I/P cluster trim plate.
- Connect the electrical connector to the dimmer switch (2).
- Connect the electrical connector to the hazard warning switch if required.
- Install the I/P trim plate to the I/P carrier. Refer to
Instrument Cluster Trim Panel Replacement
in Instrument
Panel, Gages, and Console.
- Enable the SIR system. Refer to
SIR Disabling and Enabling
and
SIR Disabling and Enabling
in SIR.