Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Power Window Schematics Connector End View Reference: Power Door Systems Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
2 |
Do the passenger windows operate properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Does the inoperative window operate from the driver window switch? | Go to Step 4 | Go to Step 5 |
4 |
Does the test lamp illuminate? | Go to Step 13 | Go to Step 9 |
5 |
Did the test lamp illuminate when the switch was pressed to the up position or the down position? | Go to Step 6 | Go to Step 10 |
6 | Did the test lamp illuminate when the switch was pressed to the up position and the down position? | Go to Step 7 | Go to Step 11 |
7 |
Does the test lamp illuminate for the up condition or the down condition? | Go to Step 8 | Go to Step 12 |
8 | Did the test lamp illuminate when the switch was pressed to the up position and the down position? | Go to Step 14 | Go to Step 16 |
9 | Test the lockout signal circuit to the inoperative window switch for an open. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 20 | Go to Step 15 |
10 | Test the up and down signal circuits between the window switches for an open. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 20 | Go to Step 15 |
11 | Test the up and down signal circuits between the window switches for a short to ground. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 20 | Go to Step 15 |
12 | Test the up and down control circuits at the inoperative window motor for an open. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 20 | Go to Step 13 |
13 | Inspect for poor connections at the passenger window switch in the door with the inoperative window. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 20 | Go to Step 18 |
14 | Inspect for poor connections at the inoperative window motor. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 20 | Go to Step 17 |
15 | Inspect for poor connections at the driver window switch. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 20 | Go to Step 19 |
16 | Repair the short to ground in one of the up or down control circuits at the inoperative window motor. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 20 | -- |
17 | Replace the inoperative window regulator motor. Refer to Front Side Door Window Regulator Motor Replacement or Rear Side Door Window Regulator Motor Replacement . Is the repair complete? | Go to Step 20 | -- |
18 | Replace the inoperative passenger window switch. Refer to Front Side Door Window Switch Replacement - Right Side . Is the repair complete? | Go to Step 20 | -- |
19 | Replace the driver window switch. Refer to Front Side Door Window Switch Replacement - Left Side . Is the repair complete? | Go to Step 20 | -- |
20 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |