Tools Required
• | J 43600 Air Conditioning Service
Center |
• | J 42220 Universal 12V Leak Detection
Lamp |
Important: Flushing with the ACR 2000 is not intended
to remove metal from the A/C system.
Flushing is intended to remove the following contaminants:
• | Desiccant, following a desiccant bag failure |
• | Refrigerant contamination |
Important: Warmer engine or ambient temperature decreases
the refrigerant recovery time during the A/C flush procedure.
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging .
- Remove the orifice tube. Refer to
Expansion (Orifice) Tube Replacement .
- Connect the A/C lines with the orifice tube removed.
- Remove the A/C compressor. Refer to
Air Conditioning Compressor Replacement .
- Install
J 45268 - 10 to the A/C
compressor hose assembly.
- Forward flow refrigerant flushing is recommended for
contaminated refrigerant or PAG oil.
Perform the following procedure:
| Important: The filter inside
J 45268 - 1 is serviceable. Remove and discard the check valve from
the filter.
|
6.1. | Service the filter with ACDelco P/N GF 470, before each flush. |
Connect
J 45268 - 1 flush filter to
the suction port of
J 45268 - 10 flush adapter.
6.2. | Connect the blue hose from
J 43600
to
J 45268 - 1 flush filter adapter. |
- Reverse flow refrigerant flushing is recommended for desiccant bag failure
only.
Perform the following procedure and replace the accumulator when
the flush is complete:
| Important: The filter inside
J 45268 - 1 is serviceable. Remove and discard the check valve from
the filter.
|
7.1. | Service the filter with ACDelco P/N GF 470, before each flush. |
Connect
J 45268 - 1 flush filter to
the discharge port of
J 45268 - 10 flush adapter.
7.2. | Connect the blue hose from
J 43600
to
J 45268 - 1 flush filter adapter. |
7.3. | Connect the red hose from
J 43600
to the suction port of
J 45268 - 10. |
Important: Close the valve on the external refrigerant
tank before starting the flush process.
- Flush the A/C system. Follow the instructions supplied with
J 43600 .
- Remove
J 45268 -10 from the A/C
compressor hose assembly.
Important: Flushing will remove all the PAG oil from
the A/C system. Replenish the A/C system with the correct amount of PAG oil.
- If the removed A/C compressor will be reinstalled, perform the following steps:
10.1. | Remove the A/C compressor drain plug. |
10.2. | Rotate the compressor input shaft to assist in draining the PAG oil from
the compressor. |
10.3. | Drain the PAG oil from the A/C compressor. |
10.4. | Install the A/C compressor drain plug. |
Tighten
Tighten the drain plug to 20N·m (15 lb ft).
- If you are replacing the A/C compressor after flushing the system, perform
the following steps:
11.1. | Do NOT drain the new PAG oil from the compressor. Deduct the amount of
PAG oil shipped with the service compressor from the amount of PAG oil listed in the
capacities table. Refer to
Refrigerant System Capacities . |
11.2. | Add the calculated amount of oil to the compressor, as needed. |
Important: Flushing will remove the fluorescent leak
detection dye from the A/C system.
- Add one bottle of
J 41447 directly to
the A/C compressor.
- Install the A/C compressor. Refer to
Air Conditioning Compressor Replacement .
- Inspect the orifice tube for debris. Clean or replace as needed.
- Install the orifice tube. Refer to
Expansion (Orifice) Tube Replacement .
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging .
- Leak test the fittings using
J 42220 .