Accessory Brackets Replacement Generator Mounting Bracket
Removal Procedure
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
- Disconnect the battery negative cable. Refer to
Battery Cable Replacement
in Engine Electrical.
- Remove the engine cooling
fan. Refer to
Fan Replacement
in Engine Cooling.
- Remove the drive belt. Refer to
Drive Belt Replacement
.
- Remove the generator. Refer to
Generator Replacement
in Engine Electrical.
- Remove the wire harness
retaining clip from the generator mounting bracket.
- Remove the drive belt tensioner. Refer to
Drive Belt Tensioner Replacement
.
- Remove the drive belt idler pulley. Refer to
Drive Belt Idler Pulley Replacement
.
- Remove the two generator mounting bracket bolts/nut from the engine.
- Slide the bracket off of the stud.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Slide the bracket
on the stud.
- Install the two generator mounting bracket bolts/nut.
Tighten
Tighten the bolts and nut to 66 N·m (49 lb ft).
- Install the drive belt
tensioner. Refer to
Drive Belt Tensioner Replacement
.
- Install the drive belt idler pulley. Refer to
Drive Belt Idler Pulley Replacement
.
- Install the wire harness retaining clip to the generator mounting
bracket.
- Install the generator. Refer to
Generator Replacement
in engine electrical.
- Install the drive belt.
Refer to
Drive Belt Replacement
.
- Install the engine cooling fan. Refer to
Fan Replacement
in Engine Cooling.
- Connect the battery negative cable. Refer to
Battery Cable Replacement
in engine electrical.
Accessory Brackets Replacement P S Pump Mounting Bracket
Removal Procedure
- Remove the engine cooling
fan. Refer to
Fan Replacement
in engine cooling.
- Remove the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical.
Important: Do not evacuate the air conditioning system.
- Remove the mounting bolts for the air conditioning compressor, if equipped.
Refer to
Air Conditioning Compressor Replacement
in HVAC.
- Move the compressor aside and support.
- Remove the drive belt idler pulley, if not equipped with A/C.
Refer to
Drive Belt Idler Pulley Replacement
in Engine Mechanical.
- Remove the power steering pump pulley. Refer to
Power Steering Pump Replacement
in Power Steering
Systems.
- Remove the rear power
steering pump bracket to front power steering pump mounting bracket bolt.
- Remove the power steering pump mounting bracket to power steering
pump bolts.
- Remove the front power steering pump mounting bracket bolts/nut
- Slide the bracket off the stud and power steering pump.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Slide the mounting
bracket on the stud and the power steering pump.
- Install the front power steering pump mounting bracket bolts and
the nut.
Tighten
Tighten the bolts and nut to 66 N·m (49 lb ft).
- Install the power steering pump mounting bracket to power steering
pump bolts.
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
- Install the rear power steering pump bracket to front
power steering pump mounting bracket bolt.
Tighten
Tighten the bolt to 25 N·m (18 lb ft).
- Install the power steering pump pulley. Refer to
Power Steering Pump Replacement
in Power Steering
Systems.
- Install the air conditioning compressor, if equipped. Refer to
Air Conditioning Compressor Replacement
in
HVAC systems with A/C-Manual.
- Install the drive belt idler pulley if not equipped with A/C.
Refer to
Drive Belt Idler Pulley Replacement
in Engine Mechanical.
- Install the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical.
- Install the engine cooling fan. Refer to
Fan Replacement
in Engine Cooling.