Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you complete the Audible Warnings Diagnostic System Check? | Go to Step 2 | ||
2 |
Did the test light illuminate? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the multi-function alarm module. Refer to Multifunction Alarm Module Replacement . Did you complete the repair? | -- | -- | |
4 | Connect the test light between the multi-function alarm module connector C2 terminal D and ground. Did the test light illuminate? | -- | Go to Step 5 | Go to Step 9 |
5 | Inspect for a faulty connection at the multi-function alarm module connector C2 terminal D. Is the connection OK? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair the faulty connection at the multi-function alarm module connector C2 terminal D. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
7 | Measure the resistance in CKT 150 between the multi-function alarm module connector C2 terminal E and ground. Is the resistance within the specified range? | 0-2 ohms | Go to Step 8 | |
8 | Repair an open in CKT 150 between the multi-function alarm module connector C2 terminal E and ground. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
9 | Repair an open in CKT 340 between the multi-function alarm module connector C2 terminal D and the fuse block. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- |