GM Service Manual Online
For 1990-2009 cars only

Step

Action

Value(s)

Yes

No

Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open.

1

  1. Turn the ignition switch to the ON position.
  2. Disconnect the turn/hazard flasher connector.
  3. Connect a test lamp between terminal 1 of the turn/hazard flasher harness connector and ground.

Does the test lamp light?

--

Go to Step 2

Go to Step 3

2

  1. Turn the LH turn signal or the RH turn signal to the ON position.
  2. Connect the fused jumper between terminal 1 and terminal 4 of the turn/hazard flasher harness connector.

Do the turn lamps illuminate but not flash?

--

Go to Step 4

Go to Step 5

3

Repair the open in CKT 539 between the fuse block and the turn/hazard flasher. Refer to Wiring Repairs

Is the repair complete?

--

System OK

--

4

Replace the turn/hazard flasher.

Is the repair complete?

--

System OK

--

5

  1. Reconnect the turn/hazard flasher connector.
  2. Disconnect the turn/hazard headlamp switch assembly.
  3. Connect fused jumper wire between terminal E and terminal F of the turn/hazard headlamp switch assembly harness connector.

Do the turn signal lamps flash?

--

Go to Step 7

Go to Step 6

6

Repair the open in CKT 16 between the turn/hazard flasher and the turn/hazard headlamp switch assembly. Refer to Wiring Repairs

Is the repair complete?

--

System OK

--

7

Replace the turn/hazard headlamp switch assembly.

Is the repair complete?

--

System OK

--