Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Do all of the fog lamps illuminate? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | -- | Go to Step 4 | Go to Step 5 |
4 | Replace the inoperative lamp. Refer to one of the following procedures: Did you complete the replacement? | -- | Go to Step 8 | -- |
5 | Connect a test lamp between the supply voltage circuit of the inoperative fog lamp and ground. Refer to Circuit Testing in Wiring Systems. Does the test lamp illuminate? | -- | Go to Step 6 | Go to Step 7 |
6 | Repair a poor connection or an open in the ground circuit of the inoperative lamp. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 8 | -- |
7 | Repair a poor connection or an open in the supply voltage circuit of the inoperative lamp. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |