Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Diagnostic System Check? | -- | ||
2 |
Do the instrument panel lamps illuminate? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | |
3 | Connect a test lamp between the circuit 8 terminal at the inoperative instrument panel lamp connector and ground. Refer to Circuit Testing in Wiring Systems. Does the test lamp illuminate? | -- | ||
4 | Repair the open in circuit 8 between the inoperative component lamp and S224. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
5 | Connect a test lamp between the inoperative component connector circuit 8 and the instrument lamp ground circuit. Refer to Circuit Testing in Wiring Systems. Does the test lamp illuminate? | -- | ||
6 | Repair an open or a poor connection in the ground circuit of the inoperative lamp. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
7 | Test for and repair a poor connection at the inoperative lamp. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and repair a poor connection? | -- | ||
8 | Replace the inoperative lamp. Did you complete the replacement? | -- | -- | |
9 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK |