The ignition system on this engine uses an individual ignition coil/module for each cylinder. The PCM controls the ignition system operation. The PCM controls each coil using one of eight Ignition Control (IC) circuits. The PCM commands the IC circuit low when a spark event is requested. This causes the IC module to energize the ignition coil to create a spark at the spark plug. Each ignition coil/module has the following circuits:
• | A power feed |
• | A ground circuit |
• | An ignition control (IC) circuit |
• | A reference low circuit |
Sequencing and timing are PCM controlled. This DTC sets when the IC circuit is out of range.
The engine is operating.
• | The PCM detects the ignition control circuit is grounded, open or shorted to a voltage. |
• | All conditions met for less than 1 second. |
• | The PCM illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The PCM records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the PCM stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the PCM records the operating conditions at the time of the failure. The PCM writes the conditions to the Freeze Frame and updates the Failure Records. |
• | The PCM turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A last test failed, or current DTC, clears when the diagnostic runs and does not fail. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Use a scan tool in order to clear the MIL and the DTC. |
Important:
• Remove any debris from the PCM connector surfaces before servicing
the PCM. Inspect the PCM connector gaskets when diagnosing/replacing the PCM.
Ensure that the gaskets are installed correctly. The gaskets prevent contaminant
intrusion into the PCM. • For any test that requires probing the PCM or component
harness connectors, use the J 35616
connector test adapter kit. Using this kit prevents any
damage to the harness connector terminals. Refer to
Using Connector Test Adapters
in Wiring Systems.
For an intermittent condition, refer to Symptoms .
The numbers below refer to the step numbers on the diagnostic table.
This step verifies that the fault is present.
This step verifies the integrity of the ignition control circuit and the PCM output.
This step tests for a short to ground on the ignition control circuit.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||
2 |
Important: If all the Ignition Control (IC) DTCs are set at the same time, inspect the IC ground circuits or the B+ circuits for an open. Does the scan tool indicate Fault? | -- | ||
3 |
Does the scan tool indicate that this diagnostic failed this ignition? | -- | Go to Diagnostic Aids | |
4 |
Is the frequency within the specified range? | 3.0-20 Hz | ||
5 | Measure the voltage at the ignition control signal circuit using the DMM. Is the voltage greater than the specified value? | 1V | ||
6 |
Does the DMM indicate continuity? | -- | ||
7 | Test the resistance from the IC circuit (at the ignition coil/module electrical connector) to ground using the DMM. Refer to Testing for Continuity in Wiring Systems. Does the DMM indicate OL? | -- | ||
8 | Probe the Ignition feed circuit for the coil/module using the test lamp J 35616-200 connected to battery ground. Refer to Probing Electrical Connectors in Wiring Systems. Does the test lamp illuminate? | -- | ||
9 | Probe the ground circuit for the coil/module using the test lamp J 35616-200 connected to B+. Refer to Probing Electrical Connectors in Wiring Systems. Does the test lamp illuminate? | -- | ||
10 | Repair the Ignition feed circuit for an open between the ignition coil/module electrical connector and the splice. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |
11 | Repair the ground circuit for an open between the ignition coil/module electrical connector and the splice. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |
12 |
Did you find and correct the condition? | -- | ||
13 | Replace the ignition coil/module. Refer to Ignition Coil Replacement in Engine Electrical . Is the action complete? | -- | -- | |
14 | Repair the Ignition Control circuit for a short to voltage. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |
15 | Repair the Ignition Control circuit for an open or grounded circuit. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |
16 |
Did you find and correct the condition? | -- | ||
17 |
Important:: Program the replacement PCM. Refer to Powertrain Control Module Replacement/Programming . Replace the PCM. Is the action complete? | -- | -- | |
18 |
Does the scan tool indicate that this test ran and passed? | -- | ||
19 | Select the Capture Info option and the Review Info option using the scan tool. Does the scan tool display any DTCs that you have not diagnosed? | -- | Go to the applicable DTC table | System OK |