The PCM supplies a bias voltage (approximately 450 mV) on the Heated Oxygen Sensor (HO2S) signal high and low circuits. When you turn the ignition to the ON position, battery voltage is supplied to the HO2S heater. As the heater reaches the operating temperature, the HO2S voltage responds by changing from a bias voltage range to the normal operation. Typically, as the HO2S reaches the operating temperature, the HO2S voltage goes from a bias voltage to a voltage below 300 mV. Depending on the exhaust gas content, it is possible for the HO2S voltage to go above 450 mV.
The PCM runs the heater test only on a cold start (depends on the cumulative air flow) and only once an ignition cycle. When you start the engine the PCM monitors the HO2S voltage. When the HO2S voltage goes above or below the bias range threshold, the PCM determines how much time it took. If the PCM detects that the process took too much time for the HO2S to enter into normal operating range, this DTC sets. The time the process takes the HO2S to reach operating temperature is based on the amount of air that flows into the engine.
• | DTCs P0101, P0102, P0103, P0112, P0113, P0117, P0118, P0121, P0122, P0123, P0125, P0200, P0335, P0336, P0351-P0358, P1258 not set. |
• | The intake air temperature and the engine coolant temperature are less than 50°C (122°F) and are within 8°C (14.5°F) of each other at engine start-up. |
• | The ignition voltage is between 10.0 volts and 18.0 volts. |
• | The AIR, EGR, and the Catalyst diagnostics are not active. |
The HO2S voltage remains between 300 mV and 700 mV for a predetermined amount of time (depends on engine coolant temperature and air flow).
• | The PCM illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The PCM records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the PCM stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the PCM records the operating conditions at the time of the failure. The PCM writes the conditions to the Freeze Frame and updates the Failure Records. |
• | The PCM turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A last test failed, or current DTC, clears when the diagnostic runs and does not fail. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Use a scan tool in order to clear the MIL and the DTC. |
Important:
• Remove any debris from the PCM connector surfaces before servicing the PCM. Inspect the PCM connector gaskets when diagnosing/replacing the PCM. Ensure that the gaskets are installed correctly. The gaskets prevent contaminant intrusion
into the PCM. • For any test that requires probing the PCM or component harness connectors, use the
J 35616
connector test adapter kit. Using this kit prevents any damage
to the harness connector terminals. Refer to
Using Connector Test Adapters
in Wiring Systems.
• | The heater diagnostic only runs on a cold start and runs once per ignition cycle. |
• | An oxygen supply inside the HO2S is necessary for proper operation. The HO2S wires provide the supply of oxygen. Inspect the HO2S wires and connections for breaks or contamination. Refer to Heated Oxygen Sensor Wiring Repairs in Wiring System. |
• | For an intermittent condition, refer to Symptoms . |
• | This diagnostic may fail due to a restriction in the secondary air injection (AIR) system. Refer to DTC P1416 Secondary Air Injection (AIR) System Bank 2 . |
The numbers below refer to the step numbers on the diagnostic table.
The engine must be allowed to cool, as the HO2S may be at operating temperature and no drop or rise in HO2S voltage would occur. If the HO2S voltage stays between 300-700 mV indicates the HO2S heater is inoperative.
If more than one HO2S heater DTC is set, this is a good indication that the HO2S fuse is open. Test all the related circuits going to all of the heated oxygen sensors for a short to ground. If all wiring is OK, it may be necessary to disconnect each HO2S one at a time to locate a shorted sensor.
Lower the exhaust system to gain sufficient access to the HO2S and/or the HO2S connector if necessary. This step verifies whether the B+ supply is available at the sensor.
This step verifies whether a ground is available at the sensor.
This step tests whether the HO2S heater element is internally open.
Inspect the ignition feed circuits at the Underhood Electrical Center for poor connections.
Test the ground circuits for an open if more then one heater DTC sets.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||
Important: If you have been operating the engine, allow the engine to cool for about one half hour before proceeding.
Does the HO2S voltage go from a bias voltage to above or below the specified values? | 300-700 mV | Go to Diagnostic Aids | ||
Inspect the fuse for the HO2S ignition feed. Is the HO2S fuse open? | -- | |||
Is the test lamp illuminated? | -- | |||
Connect the J 35616-200 test lamp between the HO2S ignition feed and the HO2S heater ground. Is the test lamp illuminated? | -- | |||
Measure the resistance between the HO2S ignition feed and the HO2S heater ground at the HO2S pigtail using the DMM. Is the HO2S resistance within the specified values? | 3.5-14.0ohms | |||
Repair the open in the HO2S ignition feed circuit to the HO2S. Refer to Wiring Repairs in Wiring Systems . Is the action complete? | -- | -- | ||
Repair the open in the HO2S heater ground circuit. Refer to Wiring Repairs in Wiring Systems . Is the action complete? | -- | -- | ||
9 |
Did you find and repair the condition? | -- | ||
10 | Replace the HO2S. Refer to Heated Oxygen Sensor Replacement - Bank 2 Sensor 2 . Is the action complete? | -- | -- | |
11 |
Is the action complete? | -- | -- | |
12 |
Does the scan tool indicate that this test ran and passed? | -- | ||
13 | Select the Capture Info option and the Review Info option using the scan tool. Does the scan tool display any DTCs that you have not diagnosed? | -- | Go to the applicable DTC table | System OK |