Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Exterior Lights Schematics | ||||||||||||
1 | Did you perform the Lighting Systems Diagnostic System Check? | -- | Go to Step 2 | |||||||||
2 | Verify that the turn signal lamps and/or indicators are inoperative. Do the turn signal lamps and/or indicators operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | ||||||||
3 | Are only the turn signal indicators in the IP cluster inoperative? | -- | Go to Step 4 | Go to Step 6 | ||||||||
4 | Test the inoperative turn signal switch signal circuit to the IP cluster for an open or high resistance. Refer to Circuit Testing in Wiring Systems. Was a problem found? | -- | Go to Step 14 | Go to Step 5 | ||||||||
5 |
Did you complete the repair? | -- | Go to Step 23 | -- | ||||||||
6 | Is only one turn signal lamp inoperative? | -- | Go to Step 7 | Go to Step 8 | ||||||||
7 | Inspect the inoperative bulb/socket for an internal short, poor terminal contact, or an open filament. Was a problem found? | -- | Go to Step 19 | Go to Step 15 | ||||||||
8 | Inspect the TURN fuse in the IP fuse block. Is the fuse open? | -- | Go to Step 13 | Go to Step 9 | ||||||||
9 |
Is the specified voltage present? | B+ | Go to Step 10 | Go to Step 16 | ||||||||
10 |
Is the specified voltage present? | B+ | Go to Step 12 | Go to Step 11 | ||||||||
11 | Test for an open or high resistance in the turn signal flasher control circuit. Refer to Circuit Testing in Wiring Systems. Was a problem found? | -- | Go to Step 17 | Go to Step 21 | ||||||||
12 |
Is continuity present? | -- | Go to Step 21 | Go to Step 20 | ||||||||
13 | Test the following circuits for a short to ground. Refer to Circuit Testing in Wiring Systems.
Was a problem found? | -- | Go to Step 18 | Go to Step 21 | ||||||||
14 | Repair the open or high resistance in the inoperative turn signal switch signal circuit to the IP cluster. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 22 | -- | ||||||||
15 | Repair the open, high resistance, or short to ground in the turn signal lamp supply voltage circuit or the open or high resistance in the turn signal lamp ground circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 22 | -- | ||||||||
16 | Repair the open or high resistance in the ignition 1 voltage circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 22 | -- | ||||||||
17 | Repair the open or high resistance in the turn signal flasher control circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 22 | -- | ||||||||
18 | Repair the short to ground found in one of the following circuits. Refer to Wiring Repairs in Wiring Systems.
Did you complete the repair? | -- | Go to Step 22 | -- | ||||||||
19 | Replace or repair the inoperative bulb/socket. Did you complete the repair? | -- | Go to Step 22 | -- | ||||||||
20 | Replace the multifunction turn signal switch. Refer to Turn Signal Switch Replacement - On Vehicle in Steering Wheel and Column - Tilt. Did you complete the repair? | -- | Go to Step 22 | -- | ||||||||
21 | Replace the hazard warning switch. Refer to Hazard Warning Switch Replacement . Did you complete the repair? | -- | Go to Step 22 | -- | ||||||||
22 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |