Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the side power door locks are inoperative. Do the power door locks operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 4 |
4 | Test for an open in CKT 295 (GRY) between the malfunctioning side door lock actuator and the body relay block. Refer to Circuit Testing in Wiring Systems. Was an open present? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair the open in CKT 295 (GRY). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 8 | Go to Step 7 |
6 | Repair the open in CKT 294 (TAN) or CKT 694 (TAN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 8 | -- |
7 | Replace the defective actuator. Refer to Front Side Door Lock Actuator Replacement and Rear Side Door Lock Actuator Replacement . Is the repair complete? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |