Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the LR power window is inoperative. Do the power windows operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is ignition voltage present in both directions? | B+ | Go to Step 4 | Go to Step 5 |
4 |
Is ignition voltage present in both directions? | B+ | Go to Step 10 | Go to Step 6 |
5 | Test CKT 168 (DK GRN) and CKT 169 (PPL) for an open. Refer to Circuit Testing in Wiring Systems. Was an open present? | -- | Go to Step 7 | Go to Step 8 |
6 | Test CKT 668 (DK BLU) and CKT 669 (BRN) for an open. Refer to Circuit Testing in Wiring Systems. Was an open present? | -- | Go to Step 7 | Go to Step 9 |
7 | Repair the open in the appropriate circuit. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 11 | -- |
8 | Replace the RH door lock and side window switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete? | -- | Go to Step 11 | -- |
9 | Replace the LR side window switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete? | -- | Go to Step 11 | -- |
10 | Replace the LR side window regulator motor. Refer to Power Window Motor Replacement . Is the repair complete? | -- | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |