Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the power door locks are inoperative. Do the power door locks operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Did the driver's door unlock? | -- | Go to Step 5 | Go to Step 4 |
4 | Check the PWR LKS fuse 14 in the IP fuse block. Is the fuse open? | -- | Go to Step 6 | Go to Step 8 |
5 | Check the MIR/LKS fuse in the underhood fuse block. Is the fuse open? | -- | Go to Step 7 | Go to Step 9 |
6 | Test CKTs 1740 (ORN), 694 (TAN), 295 (GRY), and 294 (TAN) for a short to ground. Refer to Circuit Testing in Wiring Systems. Is a short to ground present? | -- | Go to Step 14 | Go to Step 16 |
7 | Test CKTs 840 (ORN), 194 (WHT), and 195 (LT BLU) for a short to ground. Refer to Circuit Testing in Wiring Systems. Is a short to ground present? | -- | Go to Step 14 | Go to Step 16 |
8 | Test CKT 1740 (ORN) for an open. Refer to Circuit Testing in Wiring Systems. Was an open present? | -- | Go to Step 11 | Go to Step 9 |
9 | Test CKT 1050 (BLK) for an open. Refer to Circuit Testing in Wiring Systems. Was an open present? | -- | Go to Step 13 | Go to Step 15 |
10 | Test CKT 840 (ORN) for an open. Refer to Circuit Testing in Wiring Systems. Was an open present? | -- | Go to Step 12 | Go to Step 16 |
11 | Repair the open in CKT 1740 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 16 | -- |
12 | Repair the open in CKT 840 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 16 | -- |
13 | Repair the open in CKT 1050 (BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 16 | -- |
14 |
Is the repair complete? | -- | Go to Step 16 | -- |
15 | Replace the door lock relay. Is the repair complete? | -- | Go to Step 16 | -- |
16 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |