Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the RH power window is inoperative. Do the power windows operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is battery voltage present? | B+ | Go to Step 11 | Go to Step 4 |
4 |
Is battery voltage present? | B+ | Go to Step 6 | Go to Step 5 |
5 | Test CKT 164 (DK BLU) and CKT 165 (BRN), for an open. Refer to Circuit Testing in Wiring Systems. Was an open present? | -- | Go to Step 8 | Go to Step 9 |
6 | Test CKT 1001 (DK GRN) for an open. Refer to Circuit Testing in Wiring Systems. Was an open present? | -- | Go to Step 8 | Go to Step 7 |
7 | Test CKT 638 (PPL) for an open. Refer to Circuit Testing in Wiring Systems. Was an open present? | -- | Go to Step 8 | Go to Step 10 |
8 | Repair the open in the appropriate circuit. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 12 | -- |
9 | Replace the RH door lock and side window switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete? | -- | Go to Step 12 | -- |
10 | Replace the express window down module (part of the RF side window regulator motor). Is the repair complete? | -- | Go to Step 12 | -- |
11 | Replace the RF side window regulator motor. Refer to Power Window Motor Replacement . Is the repair complete? | -- | Go to Step 12 | -- |
12 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |