J 39400-A Halogen Leak Detector
12.1. | Drain the oil from both the suction and the discharge ports into a clean container. |
12.2. | Remove the compressor crankcase oil drain plug and drain the crankcase oil into the same container. |
12.3. | Measure and record the amount of oil drained from the compressor. This measurement will be used during the compressor installation procedure. |
12.4. | Properly discard the used PAG oil. |
Notice: Do not mix refrigerant oils. Use of incorrect refrigerant oil will cause compressor failure.
The CVC compressor uses a low viscosity refrigerant oil, GM P/N 12378526 (Canadian P/N 88900060).Important: NEW CVC compressor assemblies are shipped with a full poly-alkylene glycol (PAG) refrigerant oil charge. Use of the incorrect PAG oil can result in compressor failure.
If the amount of old oil drained is less than or equal to 75 ml (2.5 oz), add 75 ml of new oil into the new compressor through the crankcase bolt hole.
If the amount of old oil drained is greater than 75 ml (2.5 oz), add the equivalent amount of new oil into the new compressor through the crankcase bolt hole.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the drain plug to 16 N·m (12 lb ft).
Tighten
Tighten the top compressor bolts to 22 N·m (16 lb ft).
Tighten
Tighten the bolt to 11 N·m (8 lb ft).
J 39400-A Halogen Leak Detector
12.1. | Drain the oil from both the suction and the discharge ports into a clean container. |
12.2. | Remove the compressor crankcase oil drain plug and drain the crankcase oil into the same container. |
12.3. | Measure and record the amount of oil drained from the compressor. This measurement will be used during the compressor installation procedure. |
12.4. | Properly discard the used PAG oil. |
Important: NEW A/C compressors are shipped without a poly-alkylene glycol (PAG) refrigerant oil charge . Use of the incorrect PAG oil can result in compressor failure.
Refer to Refrigerant System Capacities .
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the drain bolt to 20 N·m (15 lb ft).
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
Tighten
Tighten the hose bolt to 33 N·m (24 lb ft).