During cranking, the ignition control (IC) module monitors the 7X crankshaft position sensor signal. Once the IC module determines spark synchronization, 3X reference signals are sent to the powertrain control module (PCM). The PCM will command all 6 injectors on for 1 priming shot of fuel in all cylinders. After the priming, the injectors are left OFF for the next 6 fuel control reference signals, or 2 crankshaft revolutions. This process allows each cylinder a chance to use the fuel from the priming shot. During this waiting period, a cam pulse will have been received by the PCM. The PCM uses the cam signal pulses to initiate sequential fuel injection. The PCM constantly monitors the number of pulses on the cam signal circuit and compares the number of cam pulses to the number of 24 X reference pulses and the number of 3 X reference pulses being received. If the PCM receives an incorrect number of pulses on the cam reference circuit, DTC P0341 will set and the PCM will initiate injector sequence without the cam signal with a 1-in-6 chance that injector sequence is correct. The engine will continue to start and run normally, although the misfire diagnostic will be affected if a misfiring condition occurs.
The engine is running, and the 3X reference pulses are being received.
The CMP sensor reference pulse is not detected during every engine cycle.
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
DTC P0341 can be caused by the secondary components leaking high voltage into the ignition module. Inspect for the following conditions:
• | An incorrect harness routing near the secondary ignition components |
• | The ignition coil arcing to the wiring harness or to the IC module--Inspect the ignition coils for cracks, for carbon tracking, or for other signs of damage. |
• | The secondary ignition wires arcing to the wiring harness |
If the condition is intermittent, refer to Intermittent Conditions .
The numbers below refer to the step numbers on the diagnostic table.
The cam signal on the scan tool should change each time the signal circuit is touched.
If the fuse is open in the jumper wire, there is a short to ground on the signal circuit.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: Engine Controls Schematics | ||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |
2 |
Does scan tool indicate the CMP sensor signal is present? | -- | Go to Step 3 | Go to Step 4 |
3 |
Does the DTC reset? | -- | Go to Step 4 | Go to Diagnostic Aids |
4 |
Does the voltage measure near the specified value? | B+ | Go to Step 6 | Go to Step 5 |
5 |
Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 12 |
6 |
Does the test lamp illuminate? | -- | Go to Step 8 | Go to Step 7 |
7 |
Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 12 |
Does cam signal change EACH time the signal circuit is touched? | -- | Go to Step 14 | Go to Step 9 | |
Did the fuse in the jumper wire open? | -- | Go to Step 11 | Go to Step 10 | |
10 | Test the signal circuit of the CMP sensor for a short to voltage or for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 12 |
11 | Test the signal circuit of the CMP sensor for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 12 |
12 | Inspect for poor connections at PCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 13 |
13 | Replace the PCM. Refer to Powertrain Control Module Replacement . Did you complete the replacement? | -- | Go to Step 16 | -- |
14 | Inspect for poor connections at CMP sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 15 |
15 | Replace CMP sensor. Refer to Camshaft Position Sensor Replacement . Did you complete the replacement? | -- | Go to Step 16 | -- |
16 |
Does the DTC run and pass? | -- | Go to Step 17 | Go to Step 2 |
17 | With a scan tool, observe the stored information, Capture Info. Does the scan tool display any DTCs that you have not diagnosed? | -- | System OK |