Removal Procedure
Important: Servicing the IP compartment door lock cylinder will result in a small
hole left in the inside top edge of the compartment door. The customer should
be advised of this before servicing the lock cylinder.
- Open the IP compartment door in order
to expose the small dimple located above the lock cylinder.
- Use a 1/8 inch drill bit in order to drill out the dimple.
- Insert the key into the lock cylinder.
- Insert a very small screw driver or pick into the drilled hole
and apply pressure to the lock cylinder release tab.
- Rotate the key in the lock cylinder using the key to pull the
lock cylinder from the IP compartment door.
Installation Procedure
- Install the lock cylinder into the instrument
panel compartment door until fully seated into place.
- Inspect the operation of the lock cylinder before closing the
IP compartment door.