GM Service Manual Online
For 1990-2009 cars only

Object Number: 613390  Size: SF
SIR Components
2000 x130 SIR
SIR Handling Caution
Handling ESD Sensitive Parts Notice

Circuit Description

The ignition switch supplies ignition voltage to the inflatable restraint sensing and diagnostic module (SDM) at terminal A1 using the AIR BAG Fuse. The ignition switch also supplies ignition voltage to the instrument cluster. The AIR BAG warning lamp is controlled by the SDM via Class 2 serial data. When the ignition switch is first turned ON, the instrument cluster flashes the AIR BAG warning lamp seven times. During this time the SDM performs tests on the SIR system then commands the instrument cluster to turn OFF the AIR BAG warning lamp after it has flashed seven times. If the ignition voltage is outside of the normal operating voltage range (9-16 V), the SDM will command the instrument cluster to turn ON the AIR BAG warning lamp with no DTCs present.

Diagnostic Aids

The loss of serial data communication between the SDM and the instrument cluster will cause the AIR BAG warning lamp to come ON solid. Refer to A Diagnostic System Check - Data Link Communications in Data Link Communications.

Test Description

The number(s) below refer to the step number(s) on the diagnostic table.

  1. This step checks to see if the AIR BAG warning lamp flashes seven times when the ignition is turned ON.

  2. This step checks to see if the scan tool can communicate with the IPC.

  3. This step checks to see if battery voltage is being supplied to the SDM.

  4. This step checks to see if the SDM connector shows any signs of corrosion, terminal damage, or poor connection.

  5. This step checks to see if there is an open or high resistance in the voltage feed circuit to the SDM.

  6. This step checks to see if there is an open or high resistance in the voltage feed circuit to the SDM Fuse.

  7. This step checks to see that the SDM is properly grounded.

AIR BAG Warning Lamp Circuit Malfunction

Step

Action

Value(s)

Yes

No

1

Did you perform the SIR Diagnostic System Check?

--

Go to Step 2

Go to Diagnostic System Check - SIR

2

Note the AIR BAG warning lamp while turning ON the ignition.

Does the AIR BAG warning lamp flash seven times?

--

Go to Step 4

Go to Step 3

3

Replace the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console.

Did you complete the repair?

--

Go to Step 10

--

4

  1. Install a scan tool.
  2. Attempt to communicate with the instrument cluster.

Can communication with the IPC be established?

--

Go to Step 5

Go to Scan Tool Does Not Communicate with Class 2 Device

5

Use the scan tool to request the SIR data list display.

Is the ignition voltage displayed on the scan tool within the specified range?

Battery voltage

Go to Step 9

Go to Step 6

6

Inspect and repair the ignition voltage feed circuit for an open or high resistance.

Did you find and correct the condition?

--

Go to Step 10

Go to Step 7

7

  1. Turn OFF the ignition.
  2. Use the DMM to measure the resistance between an SDM mounting bolt and a known good ground.

Does the resistance measure less than the specified value?

2 ohms

Go to Step 9

Go to Step 8

8

Ensure that the SDM is properly mounted and there is no corrosion on the mounting surface or mounting hardware.

Did you complete the action?

--

Go to Step 10

--

9

Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement .

Did you complete the repair?

--

Go to Step 10

--

10

  1. Reconnect all SIR and instrument cluster components.
  2. Verify that all components and connectors are properly mounted.
  3. Turn On the ignition, with the engine OFF.
  4. Use the scan tool in order to clear the DTCs.

Did you complete the action?

--

Go to Diagnostic System Check - SIR

--