This test resets HVAC control module and checks for current air temperature actuator DTC.
This checks for proper operation of coolant system to insure heater output.
Step | Action | Values | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the heating is insufficient. | ||||||||||||||||
1 | Did you perform the Vehicle Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information | ||||||||||||
Does the scan tool display DTC B0408, B0409, B0419 or B0423? | -- | Go to Step 3 | ||||||||||||||
3 | Place the blower motor switch in each speed position. Does the blower motor operate in any speed position? | -- | Go to Step 4 | Go to Blower Motor Inoperative | ||||||||||||
4 | Does the blower motor operate at the desired speeds? | -- | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||||||
5 |
Does the recirculation door move from the recirculation position to the ambient air position? | -- | Go to Step 6 | Go to Air Delivery Improper | ||||||||||||
6 | Place the passenger temperature switch in the OFF position. Does the Too Cold in Vehicle concern occur when heating or defrosting is desired? | -- | Go to Step 7 | Go to Step 9 | ||||||||||||
7 |
Does the A/C compressor operate? | -- | Go to Step 8 | |||||||||||||
Inspect the cooling system for the following conditions:
Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 9 | |||||||||||||
9 | Inspect the upper left, upper right, lower left, and lower right air temperature sensors for the following conditions:
Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 10 | ||||||||||||
10 |
Does the paper stay in place? | -- | Go to Step 11 | Go to Step 14 | ||||||||||||
11 |
Does the scan tool indicate that the sensor temperatures are within the specification at the thermometer temperatures? | -3 to 3°C (-5 to 5°F) | Go to Step 12 | Go to Step 17 | ||||||||||||
12 |
Does the scan tool indicate that the Solar Sensor parameter is greater than the specified value? | 224 Counts | Go to Step 13 | Go to Step 19 | ||||||||||||
13 |
Do the counts change? | -- | System OK | Go to Step 19 | ||||||||||||
14 |
Does the test lamp illuminate? | -- | Go to Step 18 | Go to Step 15 | ||||||||||||
15 | Test the ignition 3 voltage circuit of the inside air temperature assembly for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 16 | ||||||||||||
16 | Test the inside air temperature assembly control circuit of the inside air temperature assembly for a short to voltage, a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 20 | ||||||||||||
17 | Test the suspect temperature sensor resistance. Refer to Sensor Resistance Table . Does the resistance measure near the Sensor Resistance Table? | -- | Go to Step 20 | Go to Step 18 | ||||||||||||
18 | Inspect for poor connections at the harness connector of the suspect air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 21 | ||||||||||||
19 | Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 22 | ||||||||||||
20 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 23 | ||||||||||||
21 | Replace the appropriate temperature sensor. Refer to the following procedures: Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||||
22 | Replace the sunload sensor. Refer to Sun Load Sensor Replacement . Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||||
23 |
Important: Perform the recalibration procedure for the HVAC control module. Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||||
24 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |