GM Service Manual Online
For 1990-2009 cars only

Test Description

  1. This test resets HVAC control module (IPM) and tests for the current air temperature DTC.

  2. The ambient air temperature must be above 3°C (38°F).

  3. The specified values are from the A/C System Performance Test

Step

Action

Values

Yes

No

Schematic Reference: HVAC Schematics

DEFINITION: The cooling is insufficient.

1

Did you perform the HVAC Diagnostic System Check?

--

Go to Step 2

Go to Diagnostic System Check - HVAC Systems - Automatic

2

  1. Install a scan tool.
  2. Turn ON the ignition, with the engine OFF.
  3. Recalibrate the motors. Refer to Actuator Recalibration .
  4. Observe the current DTC list in Heating, Ventilation and Air Conditioning using the scan tool.

Does the scan tool display DTC B1340 or B1341?

--

Go to Diagnostic Trouble Code (DTC) List

Go to Step 3

3

Place the blower motor switch in each speed position.

Does the blower motor operate in each speed position?

--

Go to Step 4

Go to Blower Motor Inoperative

4

Does the blower motor provide sufficient air flow?

--

Go to Step 5

Go to Blower Motor Malfunction

5

  1. Place the mode switch in the bi-level position.
  2. Alternately, place the recirculation switch in the recirculation and ambient air positions.

Does the recirculation door move from the recirculation position to the ambient air position?

--

Go to Step 6

Go to Air Recirculation Malfunction

6

Does the Too Hot in Vehicle concern occur when A/C requested?

--

Go to Step 7

Go to Step 9

7

Important: Ambient air temperature must be above 3°C (38°F).

  1. Cover the sunload sensor.
  2. Start the engine.
  3. Open all panel outlets in order to allow maximum air flow.
  4. Place the air temperature switch in the coldest position.
  5. Select vent mode.
  6. Place the blower motor switch in the maximum speed.
  7. Ensure that the ambient air mode indicator is not illuminated.

Does the A/C compressor clutch engage?

--

Go to Step 8

Go to HVAC Compressor Clutch Does Not Engage

8

Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test in Heating and Air Conditioning.

Are pressure values within specifications for the ambient air temperature, and within 103 kpa (15 psi) of each other?

--

Go to Step 9

Go to Leak Testing in Heating, Ventilation and Air Conditioning

9

  1. Turn ON the ignition, with engine OFF.
  2. With a scan tool, command the right and left air temperature actuators Hot and Cold.
  3. Observe the Right Temp Door Position and the Left Temp Door Position parameters.

Do the counts change when actuators are commanded?

--

Go to Step 10

Go to Step 16

10

Check the air temperature sensors for proper installation. Refer to the following procedures:

Did you find and correct the condition?

--

Go to Step 26

Go to Step 11

11

Inspect for airflow through the inside air temperature assembly by placing a 5 cm (2 in) square piece of paper over the sensor air inlet.

Does the paper stay in place?

--

Go to Step 12

Go to Step 18

12

  1. Install a thermometer near the four air temperature sensors and the inside air temperature assembly.
  2. With a scan tool, observe the following parameters in the Heating and A/C Data list:
  3. • Left AC Duct Temp
    • Left Htr. Duct Temp
    • Right AC Duct Temp
    • Right Htr. Duct Temp
    • Inside Air Temp

Does the scan tool indicate that the sensor temperatures are within the specifications at the thermometer temperatures?

-3 to +3°C

(-5 to +5°F)

Go to Step 13

Go to Step 15

13

  1. Turn OFF the engine.
  2. Install a scan tool.
  3. Cover the sunload sensor.
  4. Start the engine.
  5. Adjust driver side temperature to 22°C (72°F).
  6. With a scan tool, observe the Solar Sensor data parameter in the Heating and Air Conditioning data list.

Does the scan tool indicate that the solar sensor parameter is greater than the specified value?

230 Counts

Go to Step 14

Go to Step 19

14

  1. Uncover the sunload sensor.
  2. Direct a light source at the sunload sensor.

Do the counts change?

--

Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems

Go to Step 19

15

Test the suspect temperature sensor resistance. Refer to Sensor Resistance Table .

Does the resistance measure near the Sensor Resistance Table?

--

Go to Step 21

Go to Step 18

16

Test the suspect actuator door control circuit for a short to voltage, short to ground, open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 26

Go to Step 17

17

Test the suspect actuator ignition 3 voltage circuit for a short to ground, open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 26

Go to Step 20

18

Inspect for poor connections at the harness connector of the suspect air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 26

Go to Step 22

19

Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 26

Go to Step 23

20

Inspect for poor connections at the harness connector of the suspect air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 26

Go to Step 24

21

Inspect for poor connections at the harness connector of the IPM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 26

Go to Step 25

22

Replace the suspect temperature sensor. Refer to Air Temperature Sensor Replacement - Upper Left Side , Air Temperature Sensor Replacement - Upper Right Side , Air Temperature Sensor Replacement - Lower Left Side , Air Temperature Sensor Replacement - Lower Right Side or Inside Air Temperature Sensor Replacement .

Did you complete the replacement?

--

Go to Step 26

--

23

Replace the sunload sensor. Refer to Sun Load Sensor Replacement .

Did you complete the replacement?

--

Go to Step 26

--

24

Important: Perform the recalibration procedure for the air temperature actuator.

Replace the suspect air temperature actuator. Refer to Air Temperature Actuator Replacement - Right Side or Air Temperature Actuator Replacement - Left Side .

Did you complete the replacement?

--

Go to Step 26

--

25

Important: Perform the recalibration procedure for the IPM.

Replace the IPM. Refer to HVAC Control Module Replacement .

Did you complete the replacement?

--

Go to Step 26

--

26

Operate the system in order to verify the repair.

Did you correct the condition?

--

System OK