The number(s) below refer to the step number(s) on the diagnostic table.
Listen for an audible click when the auxiliary blower motor relay operates. Command both the ON and OFF states. Repeat the commands as necessary.
Tests for voltage at the coil side of the auxiliary blower motor relay. The RR BLO fuse supplies power to the coil side of the auxiliary blower motor relay.
Verifies that the rear integration module (RIM) is providing ground to the auxiliary blower motor relay.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The auxiliary blower motor is inoperative in all speed positions. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the auxiliary blower motor operate in any speed position? | Go to Step 3 | |
Does the auxiliary blower motor relay turn ON and OFF with each command? | Go to Step 9 | Go to Step 4 | |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 15 | |
Does the test lamp turn ON and OFF with each command? | Go to Step 17 | Go to Step 6 | |
6 | Does the test lamp remain illuminated with each command? | Go to Step 8 | Go to Step 7 |
7 | Test the control circuit of the auxiliary blower motor relay for a short to voltage or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 19 |
8 | Test the control circuit of the auxiliary blower motor relay for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 19 |
9 |
Does the test lamp illuminate? | Go to Step 18 | Go to Step 10 |
10 | Connect a test lamp between the auxiliary blower motor supply voltage circuit and ground. Does the test lamp light? | Go to Step 13 | Go to Step 11 |
11 | Test the battery positive voltage circuit of the auxiliary blower motor for an open or short to ground. Refer to Circuit Testing and Wiring Repairs in wiring systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 12 |
12 | Test the battery positive voltage circuit of the auxiliary blower motor relay for an open or short to ground. Refer to Circuit Testing and Wiring Repairs in wiring systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 17 |
13 | Test the high speed blower motor control circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in wiring systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 14 |
14 | Test the ground circuit of the auxiliary HVAC control assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 16 |
15 | Repair the ignition 3 voltage circuit of the auxiliary blower motor relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
16 | Inspect for poor connections at the auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 20 |
17 | Inspect for poor connections at the auxiliary blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 21 |
18 | Inspect for poor connections at the auxiliary blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 22 |
19 | Inspect for poor connections at the harness connector of the rear integration module (RIM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 23 |
20 | Replace the auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Module Replacement . Did you complete the replacement? | Go to Step 24 | -- |
21 | Replace the auxiliary blower motor relay. Did you complete the replacement? | Go to Step 24 | -- |
22 | Replace the auxiliary blower motor. Refer to Auxiliary Blower Motor Replacement in Heating Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 24 | -- |
23 |
Important: Perform the set up procedure for the rear integration module (RIM). Replace the rear integration module (RIM). Refer to Rear Integration Body Control Module Replacement . Did you complete the replacement? | Go to Step 24 | -- |
24 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |