Mode Valve Actuator Replacement LHD
Removal Procedure
- Remove the instrument panel (IP) carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gauges
and Console.
Important: The temperature door motor does not need to be removed in order to remove
the mode actuator motor.
The temperature door motor in the graphic is removed in order to show
the fastener locations clearly.
- Remove the mode actuator
retaining fasteners (1).
- Remove the mode actuator.
- Note the position of the door levers in relation to the cam.
The mode door levers must be in the same position in order to reassemble
the mode actuator to the HVAC case.
Installation Procedure
- Lubricate the pivots on the mode door levers and the channels
on the mode motor cam before reassembling.
- Align the mode door levers
with the cam slots, as noted on disassembly.
- Install the mode actuator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the mode
actuator retaining fasteners (1).
Tighten
Tighten the fasteners to 1.4 N·m (12 lb in).
- Install the IP carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gauges and Console.
- Recalibrate the actuators. Refer to
Body Control Module (BCM) Programming/RPO Configuration
in Body Controls System.
Mode Valve Actuator Replacement RHD
Removal Procedure
- Remove the IP carrier.
Refer to
Instrument Panel Carrier Replacement
in
Instrument Panel, Gauges and Console.
- Remove the electrical connector from the passenger air mix actuator.
- Remove the passenger air mix actuator retaining fasteners (1).
- Remove the passenger air
mix actuator.
- Remove the mode actuator
retaining fasteners (1).
- Remove the mode actuator electrical connector.
- Remove the mode actuator.
- Note the position of the door levers to the cam.
The mode door levers must be in the same position in order to reassemble
the mode actuator to the HVAC case.
Installation Procedure
- Lubricate the pivots on the mode door levers and the channels
on the mode motor cam before reassembling.
- Install the mode actuator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the mode
actuator retaining fasteners (1).
Tighten
Tighten the fasteners to 1.4 N·m (12 lb in).
- Install the mode actuator electrical connector.
- Install the passenger
air mix actuator.
- Install the passenger
air mix actuator retaining fasteners (1).
- Install the electrical connector to the passenger air mix actuator.
- Install the IP carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gauges and Console.
- Recalibrate the actuators. Refer to
Body Control Module (BCM) Programming/RPO Configuration
in Body Controls System.