The heated oxygen sensor (HO2S) is a sensor used to detect the oxygen content in the exhaust. The powertrain control module (PCM) supplies the sensor with a signal circuit and a ground circuit. The PCM supplies a bias voltage between the circuits. The sensor varies the voltage based on the oxygen content in the exhaust. When the exhaust stream is lean (more oxygen), the sensor produces a low voltage signal. When the exhaust stream is rich (less oxygen), the sensor produces a high voltage signal. The PCM monitors the HO2S signal during Closed Loop. In order to correct for rich or lean conditions, the PCM adjusts the injector pulse width. This diagnostic trouble code (DTC) indicates that the signal frequency of the HO2S indicates an active sensor (Closed Loop), but the amplitude (voltage) of the signal remains within an incorrect range.
• | DTCs P0101, P0102, P0103, P0106, P0107, P0108, P0117, P0118, P0121, P0122, P0123, P0125, P0131, P0132, P0133, P0134, P0151, P0152, P0153, P0154, P0201-P0208, P1133, P1134, P1153, or P1154 are not set. |
• | The coolant temperature is greater than 75°C (176°F). |
• | The engine is running for 120 seconds (2 minutes). |
• | The system voltage is between 10-18 volts. |
• | The predicted oxygen sensor (O2) heater temperature is 600°C (1112°F). |
• | The traction control is inactive. |
• | The Catalyst Protection Mode is inactive. |
• | The engine speed is between 500-5,000 RPM. |
• | The mass air flow (MAF) is between 3-30 g/s. |
• | All conditions above are met for 5 seconds. |
• | The closed loop fuel control is enabled. |
• | The vehicle is in Closed Loop fuel control, based on the HO2S voltages switching from below 350 mV to above 500 mV. |
• | The PCM monitors the HO2S voltages for 120 seconds (2 minutes). |
• | During the 120 second monitoring period, the voltage remains within 350-500 mV for approximately 16 seconds. |
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
If the problem is intermittent, refer to Intermittent Conditions .
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Engine Controls Schematics | ||||||||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |||||||
2 |
Does the scan tool indicate HO2S voltage varying outside the specified values? | 350-500 mV | Go to Step 3 | Go to Step 4 | ||||||
3 |
Does the scan tool indicate that this test passed? | -- | Go to Intermittent Conditions | Go to Step 4 | ||||||
4 |
Does the scan tool indicate an HO2S voltage below the specified value? | 150 mV | Go to Step 6 | Go to Step 5 | ||||||
5 |
Did you find and correct the condition? | -- | Go to Step 9 | Go to Step 8 | ||||||
6 |
Did you find and correct the condition? | -- | Go to Step 9 | Go to Step 7 | ||||||
7 | Replace affected HO2S. Refer to Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 or Heated Oxygen Sensor Replacement - Bank 2 Sensor 1 Did you complete the replacement? | -- | Go to Step 9 | -- | ||||||
8 | Replace the PCM. Refer to Powertrain Control Module Replacement . Did you complete the replacement? | -- | Go to Step 9 | -- | ||||||
9 |
Does the DTC run and pass? | -- | Go to Step 10 | Go to Step 2 | ||||||
10 | With a scan tool, observe stored information, Capture Info. Does the scan tool display any DTCs that you have not diagnosed? | -- | System OK |