The RKE module runs this internal self-test at power up. This test will only be run if B1982 - Battery voltage high or B1983 - Battery voltage low are not current. This DTC will set as a current DTC only.
The RKE module will set this DTC if it fails the internal Read Only Memory (ROM) to Random Access Memory (RAM) write test.
Stores a DTC B1000 in the RKE current memory.
No driver warning message will be displayed for this DTC.
The RKE module will clear this DTC after a passed test message is received after the power up self-test.
This DTC will stay in memory until it receives a passed test message after the power up self-test. If this DTC will not clear, replace the RKE module.
The numbers below refer to steps on the diagnostic table:
Perform the Remote Keyless Entry Diagnostic System Check before diagnosing DTC B1000.
This step is to attempt to clear the DTC.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Were you sent here from Remote Keyless Entry Diagnostic System Check? | -- | Go to | ||
Disconnect connector and reconnect from RKE module to cycle power. Is DTC B1000 still present? | -- | Go to | ||
3 | Replace the RKE module. Refer to Remote Control Door Lock Receiver Replacement . Is repair complete? | -- | Go to | -- |