Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the scan tool communicate with the RKE system? | -- | ||
2 |
Are any RKE Bxxx DTCs stored? If any Uxxxx codes are present refer to Diagnostic Trouble Code (DTC) List/Type . | -- | ||
3 | Attempt to establish communications with the other systems connected to the same serial data line (PCM, RIM, ABS, IPC, etc.). Does the scan tool communicate with the other systems? | -- | Go to Scan Tool Diagnostics | |
4 | Operate the transmitter through all button functions. Is the transmitter functioning properly? | -- | System OK | |
5 |
Is the voltage within the specified range? | 10-15 V | ||
6 | Check for voltage between the RKE module terminal D (w/o AU5) or terminal C (w/ AU5). Is the voltage within the specified range? | 10-15 V | ||
7 | Check for continuity between the RKE module connector terminal B and C (w/o AU5) or terminal B and D (w/o AU5) and the DLC terminal 2. Is there continuity? | -- | ||
8 |
Is the repair complete? | -- | -- | |
9 | Repair the open or short to ground in CKT 540 (ORN). Is the repair complete? | -- | -- | |
10 | Repair the open in CKT 1807 (PPL). Is the repair complete? | -- | -- | |
11 | Repair the open in CKT 1351 (BLK). Is the repair complete? | -- | -- | |
12 |
Are all DTCs cleared? | -- | System OK | -- |