Removal Procedure
- Remove the HVAC Module. Refer to
HVAC Module Assembly Replacement
.
- Remove the mode actuator. Refer to
Mode Actuator Replacement
in HVAC Systems -- Automatic.
- Remove the left temperature actuator. Refer to
Air Temperature Actuator Replacement - Left Side
in HVAC Systems --
Automatic.
- Remove the fasteners that retain the mode actuator bracket.
- Remove the mode actuator bracket.
- Remove the upper module case fasteners in order to access the
door.
- Open the module.
- Remove the actuator cam
from the door.
- Remove the defroster door.
Installation Procedure
- Install the defroster door.
- Install the actuator cam
to the mode door.
- Close the module case.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the module
case fasteners.
Tighten
Tighten the fasteners to 1.4 N·m (12 lb in).
- Install the mode actuator and bracket. Refer to
Mode Actuator Replacement
in HVAC Systems -- Automatic.
- Install the HVAC module. Refer to
HVAC Module Assembly Replacement
.