Air Conditioning Evaporator Hose Assembly Replacement LHD
Tools Required
J 39400 Electronic
Halogen Leak Detector
Removal Procedure
- Recover the refrigerant
from the system. Refer to
Refrigerant Recovery and Recharging
.
- Disconnect the evaporator hose assembly from the accumulator.
- Disconnect the evaporator hose assembly from the strut tower.
- Disconnect the evaporator
hose assembly from the evaporator core line fitting.
- Disconnect the temperature sensor electrical connector.
- Remove the upper filler panel. Refer to
Filler Panel Replacement - Upper
in Body Front End.
- Disconnect the evaporator
hose assembly from the condenser.
- Remove the evaporator hose assembly.
Installation Procedure
- Install the evaporator
hose assembly to the vehicle.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Connect the evaporator
hose assembly to the condenser.
Tighten
Tighten the evaporator hose assembly to 20 N·m (15 lb ft).
- Connect the evaporator
hose assembly to the evaporator core.
Tighten
Tighten the evaporator hose assembly to 20 N·m (15 lb ft).
- Connect the evaporator
hose assembly to the accumulator.
Tighten
Tighten the evaporator hose assembly to 20 N·m (15 lb ft).
- Connect the evaporator hose assembly to the strut tower.
- Connect the temperature sensor electrical connector.
- Recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the repaired or reinstalled component
using J 39400
.
- Install the upper filler panel. Refer to
Filler Panel Replacement - Upper
in Body Front End.
Air Conditioning Evaporator Hose Assembly Replacement RHD
Tools Required
J 39400 Electronic
Halogen Leak Detector
Removal Procedure
- Recover the refrigerant
from the system. Refer to
Refrigerant Recovery and Recharging
.
- Disconnect the evaporator hose assembly from the accumulator.
- Disconnect the evaporator hose assembly from the strut tower.
- Disconnect the evaporator
hose assembly from the evaporator core line fitting.
- Disconnect the temperature sensor electrical connector.
- Remove the upper filler panel. Refer to
Filler Panel Replacement - Upper
in Body Front End.
- Remove the master cylinder. Refer to
Master Cylinder Replacement
in Hydraulic Brakes.
- Remove the hydraulic brake booster. Refer to
Power Brake Booster Replacement
in Hydraulic Brakes.
- Disconnect the evaporator
hose assembly from the condenser.
- Remove the evaporator hose assembly.
Installation Procedure
- Install the evaporator
hose assembly to the vehicle.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Connect the evaporator
hose assembly to the condenser.
Tighten
Tighten the evaporator hose assembly to 20 N·m (15 lb ft).
- Connect the evaporator
hose assembly to the evaporator core.
Tighten
Tighten the evaporator hose assembly to 20 N·m (15 lb ft).
- Connect the evaporator
hose assembly to the accumulator.
Tighten
Tighten the evaporator hose assembly to 20 N·m (15 lb ft).
- Connect the evaporator hose assembly to the strut tower.
- Install the master cylinder. Refer to
Master Cylinder Replacement
in Hydraulic Brakes.
- Install the hydraulic brake booster. Refer to
Power Brake Booster Replacement
in Hydraulic Brakes.
- Connect the temperature sensor electrical connector.
- Recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the repaired or reinstalled component
using J 39400
.
- Install the upper filler panel. Refer to
Filler Panel Replacement - Upper
in Body Front End.