Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 |
Does the scan tool communicate with the modules? | -- | ||||||||
2 | Select display module DTC function with the scan tool. Are any DTCs stored? | -- | System OK | |||||||
3 | Are any Loss of Class 2 Serial Data Communication DTCs set? (Loss of Class 2 Serial Data Communication DTCs have the form UXXXX.) | -- | Go to Diagnostic Trouble Code (DTC) List in Data Link Communications | |||||||
4 | Attempt to establish communications with the other modules connected to the serial data line (PCM, IPC, etc.). Does the scan tool communicate with the other modules? | -- | Go to Scan Tool Does Not Communicate with Class 2 Data Line in Data Link Communications | |||||||
5 | Test the module circuits for an open or short to ground. Was an open or short found? | -- | ||||||||
6 |
Does the test light turn on in all circuits? | -- | ||||||||
7 | Locate and repair the open in the module ground circuit. Is the repair complete? | -- | -- | |||||||
8 | Locate and repair the open in the module power circuit. Is the repair complete? | -- | -- | |||||||
9 | Replace the module. Refer to one of the following: Is the repair complete? | -- | -- | |||||||
10 |
Are all DTCs cleared? | System OK |