Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Measure the voltage between connector terminal B CKT 745 (GRY/BLK) and ground. Does the measured voltage equal the specified value? | 10-15V | Go to Step 5 | Go to Step 3 |
3 | Inspect CKT 745 (GRY/BLK) for an open or a short to ground. Is the wiring OK? | -- | Go to Step 6 | Go to Step 4 |
4 | Repair the wiring on CKT 745 (GRY/BLK). Did you complete the repair? | -- | -- | |
5 | Measure the voltage between the left front door latch assembly connector terminal B CKT 745 (GRY/BLK) and terminal D CKT 351 (BLK/WHT) Does the measured voltage equal the specified value? | 10-15V | Go to Step 10 | Go to Step 8 |
6 | Inspect the connector C2 terminal B for proper terminal contact. Is the terminal OK? | -- | Go to Step 7 | Go to Step 12 |
7 | Replace the driver door module. Did you complete the repair? | -- | -- | |
8 | Inspect CKT 351(BLK/WHT) for an open. Is the wiring OK? | -- | Go to Step 9 | |
9 | Repair the wiring on CKT 351 (BLK/WHT). Did you complete the repair? | -- | -- | |
10 | Inspect the left front door latch assembly connector for proper terminal contact. Is the terminal OK? | -- | Go to Step 11 | Go to Step 12 |
11 | Replace the left from the door latch assembly. Did you complete the repair? | -- | -- | |
12 | Repair the poor terminal contact. Did you complete the repair? | -- | -- |