Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the entire Backup Lights System Check performed? | -- | Go to Backup Lamp System Check | |
2 |
Is the voltage within the specified range? | 10-15 V | ||
3 | Connect a DMM from the suspect backup lamp connector cavity A (LT GRN) to cavity G (BLK). Is the voltage within specified range? | 10-15 V | ||
4 | Replace the suspect backup lamp. Refer to Backup Lamp Replacement . Is the backup lamp replacement complete? | -- | Go to Backup Lamp System Check | -- |
5 | Repair the open in CKT 24 (LT GRN) between S410 and the suspect backup lamp. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | Go to Backup Lamp System Check | -- |
6 | Repair the open in CKT 850 (BLK) between S413 and the suspect backup lamp. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | Go to Backup Lamp System Check | -- |