Instrument Panel Outer Air Outlet Upper Duct Replacement - Left Side Right Hand Drive
Removal Procedure
- Remove the instrument panel (I/P) retainer. Refer to
Instrument Panel Retainer Replacement.
- Disconnect the wiring harness from the air duct.
- Remove the screws (1) that retain the air duct.
- Remove the left air duct (2), by unsnapping the duct from the HVAC module.
Installation Procedure
- Install the left air duct (2), by pressing down until you hear the tabs engage on the HVAC module.
Caution: Refer to Fastener Caution in the Preface section.
- Install the air outlet duct screws (1).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the wiring harness to the air duct.
- Install the I/P retainer. Refer to
Instrument Panel Retainer Replacement.
Instrument Panel Outer Air Outlet Upper Duct Replacement - Left Side Left Hand Drive
Removal Procedure
- Remove the instrument panel (I/P) retainer. Refer to
Instrument Panel Retainer Replacement.
- Remove the dash insulator (1).
- Disconnect the wiring harness from the air duct.
- Remove the screws (1) that retain the air duct.
- Remove the left air duct (2), by unsnapping the duct from the HVAC module.
Installation Procedure
- Install the left air duct (2), by pressing down until you hear the tabs engage on the HVAC module.
Caution: Refer to Fastener Caution in the Preface section.
- Install the air outlet duct screws (1).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the wiring harness to the air duct.
- Install the dash insulator (1).
- Install the I/P retainer. Refer to
Instrument Panel Retainer Replacement.