Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 |
Does the scan tool indicate that a lower air quality number can be selected to increase the sensitivity level of the air quality sensor? | Go to Step 3 | Go to Step 4 |
3 | Adjust the sensitivity level to increase the sensitivity of the air quality sensor. Refer to Air Quality Calibration Offset . Operate the system in order to verify the condition. Did you correct the condition? | Go to Step 17 | Go to Step 4 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 12 |
5 | With a test lamp connected to battery voltage probe the low reference circuit at the Air Quality Sensor connector. Does the test lamp illuminate? | Go to Step 6 | Go to Step 13 |
6 | With a test lamp connected to ground probe the ignition 1 voltage circuit at the Air Quality Sensor connector. Does the test lamp illuminate? | Go to Step 7 | Go to Step 14 |
7 | With a volt meter inspect the air quality Nox sensor signal circuit and the air quality HC sensor signal circuit at the Air Quality Sensor connector. Does the volt meter display near 5 volts or greater on either circuit? | Go to Step 8 | Go to Step 9 |
8 | Test the appropriate 5-volt sensor signal circuit of the Air Quality Sensor for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 10 |
9 | Test the appropriate 5-volt sensor signal circuit of the Air Quality Sensor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 11 |
10 | Inspect for poor connections at the harness connector of the Air Quality Sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 15 |
11 | Inspect for poor connections at the harness connector of the HVAC Control Module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 16 |
12 | Repair the ground circuit of the Air Quality Sensor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | -- |
13 | Repair the low reference circuit of the Air Quality Sensor for an open, high resistance or short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | -- |
14 | Repair the ignition 1 voltage circuit of the Air Quality Sensor for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | -- |
15 | Replace the Air Quality Sensor. Refer to Outside Air Quality Sensor Replacement . Did you complete the replacement? | Go to Step 17 | -- |
16 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 17 | -- |
17 | Operate the system in order to verify the repair. Did you correct the condition? | Go to Step 2 | System OK |