• | The condition may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections . |
• | Inspect the air delivery system for the following conditions: |
• | A dirty HVAC air filter |
• | An obstruction to the airflow |
• | Air leaks |
• | Misaligned air ducts |
• | Broken or binding linkages or doors |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 | Place the blower motor switch in each speed position. Does the blower motor operate in any of the speed positions? | Go to Step 3 | Go to Blower Motor Malfunction |
3 |
Does the recirculation door move from the recirculation position to the outside air position? | Go to Step 4 | |
4 |
Does the drive shaft of the mode actuator rotate? | Go to Diagnostic Aids | Go to Step 5 |
5 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
6 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |