Scan Tool Output Control
| Additional Menu Selection(s)
| Description
|
1- 2 Solenoid
| --
|
• | The TCM commands the 1-2 shift solenoid valve ON and OFF. The
scan tool 1-2 Sol. parameter should match the commanded state. The scan
tool Commanded Gear parameter should correspond with the shift solenoid combination.
Refer to
Shift Solenoid Valve State and Gear Ratio
. |
• | When the ignition is ON, and the engine is OFF, there are no limits
to this control. The solenoid remains ON until commanded OFF, and vice versa. When
the output control is exited, the solenoid state is determined by the TCM. |
• | When the engine is running, the following control limits apply: |
- | Only sequential gear changes are allowed. For example, 1st to 3rd is
not allowed. If a non-sequential gear change is attempted, the message "Non-sequential
gear changes not allowed. Gear changes must be in order" appears on the scan
tool display. |
- | The vehicle speed must be below a calibrated value. If the vehicle
speed is too high, the message "Vehicle speed too high" appears on
the scan tool display. |
- | The engine speed must be below a calibrated value. If the engine speed
is too high, the message "Engine speed too high" appears on the scan
tool display. |
- | Downshifts are allowed only when the vehicle speed is below a calibrated
value. If the vehicle speed is too high, the message "Eng. is on and veh.
speed too hi for 3-2 or 2-1 downshift" appears on the scan
tool display. |
- | The gear requested may not be greater than the current selected transmission
range. For example, 3rd gear is not allowed if the transmission range is D2. If
the gear requested is greater than the current selected transmission range, the
message "Eng. running and gear request is greater than the current TR"
appears on the scan tool display. |
- | The solenoid remains ON until commanded OFF, and vice versa. When the
output control is exited, the solenoid state is determined by the TCM. |
|
2- 3 Solenoid
| --
|
• | The TCM commands the 2-3 shift solenoid valve ON and OFF. The
scan tool 2-3 Sol. parameter should match the commanded state. The scan
tool Commanded Gear parameter should correspond with the shift solenoid combination.
Refer to
Shift Solenoid Valve State and Gear Ratio
. |
• | When the ignition is ON, and the engine is OFF, there are no limits
to this control. The solenoid will remain ON until commanded OFF, and vice versa.
When the output control is exited, the solenoid state is determined by the TCM. |
• | When the engine is running, the following control limits apply: |
- | Only sequential gear changes are allowed. For example, 1st to 3rd is
not allowed. If a non-sequential gear change is attempted, the message "Non-sequential
gear changes not allowed. Gear changes must be in order" appears on the scan
tool display. |
- | The vehicle speed must be below a calibrated value. If the vehicle
speed is too high, the message "Vehicle speed too high" appears on
the scan tool display. |
- | The engine speed must be below a calibrated value. If the engine speed
is too high, the message "Engine speed too high" appears on the scan
tool display. |
- | Downshifts are allowed only when the vehicle speed is below a calibrated
value. If the vehicle speed is too high, the message "Eng. is on and veh.
speed too hi for 3-2 or 2-1 downshift" appears on the scan
tool display. |
- | The gear requested may not be greater than the current selected transmission
range. For example, 3rd gear is not allowed if the transmission range is D2. If
the gear requested is greater than the current selected transmission range, the
message "Eng. running and gear request is greater than the current TR"
appears on the scan tool display. |
- | The solenoid remains ON until commanded OFF, and vice versa. When the
output control is exited, the solenoid state is determined by the TCM. |
|
4- 5 Solenoid
| --
|
• | The TCM commands the 4-5 shift solenoid valve ON and OFF. The
scan tool 4-5 Sol. parameter should match the commanded state. The scan
tool Commanded Gear parameter should correspond with the shift solenoid combination.
Refer to
Shift Solenoid Valve State and Gear Ratio
. |
• | When the ignition is ON, and the engine is OFF, there are no limits
to this control. The solenoid will remain ON until commanded OFF, and vice versa.
When the output control is exited, the solenoid state is determined by the TCM. |
• | When the engine is running, the following control limits apply: |
- | Only sequential gear changes are allowed. For example, 1st to 3rd is
not allowed. If a non-sequential gear change is attempted, the message "Non-sequential
gear changes not allowed. Gear changes must be in order" appears on the scan
tool display. |
- | The vehicle speed must be below a calibrated value. If the vehicle
speed is too high, the message "Vehicle speed too high" appears on
the scan tool display. |
- | The engine speed must be below a calibrated value. If the engine speed
is too high, the message "Engine speed too high" appears on the scan
tool display. |
- | Downshifts are allowed only when the vehicle speed is below a calibrated
value. If the vehicle speed is too high, the message "Eng. is on and veh.
speed too hi for 3-2 or 2-1 downshift" appears on the scan
tool display. |
- | The gear requested may not be greater than the current selected transmission
range. For example, 3rd gear is not allowed if the transmission range is D2. If
the gear requested is greater than the current selected transmission range, the
message "Eng. running and gear request is greater than the current TR"
appears on the scan tool display. |
- | The solenoid remains ON until commanded OFF, and vice versa. When the
output control is exited, the solenoid state is determined by the TCM. |
|
Reset Transmission Adapts
| --
|
• | The TCM clears, or resets, all TAP cells to zero. |
• | There are no limits to using this control. It may be performed with
the engine running or when the ignition is ON, and the engine is OFF. |
|
Reset Transmission
| --
|
• | The TCM resets the amount of oil life remaining to 100 percent. |
• | There are no limits to using this output control. It may be performed
with the engine running or when the ignition is ON, and the engine is OFF. |
|
PC Solenoid
| --
|
• | The TCM commands the amperage to the pressure control solenoid in order
to control transmission line pressure. As the amperage increases, the line pressure
decreases. As the amperage decreases, the line pressure increases. The amperage
range is 0.10-1.10 and may be commanded in one-tenth amp increments. |
• | When the ignition is ON, and the engine is OFF, the reference, commanded,
amperage may be controlled within calibrated limits. The scan tool parameter "PC
Sol. Ref. Current" changes, but the parameter "PC Sol. Actual Current"
does not change. The reference current remains until commanded otherwise. |
• | When the engine is running, the following control limits apply: |
- | When the transmission range is Park or Neutral, the reference, commanded,
amperage may be controlled within calibrated limits. The engine speed must be less
than 1,500 RPM. If the engine speed is greater than 1,500 RPM, the
message "TR in park/neutral and engine speed over 1,500 RPM"
appears on the scan tool display. Both the scan tool parameters "PC Sol. Ref.
Current" and "PC Sol. Actual Current" change. Both current readings
remain until commanded otherwise. |
- | When the transmission range is not in Park or Neutral, the reference
amperage can only be controlled less than the current determined by the TCM.
The TCM does not allow a value to be selected that may cause damage to the transmission.
If the requested amperage is more than allowed by the TCM, the message "Requested
current for the PC Solenoid is too high" appears on the scan tool display. |
- | Transmission IMS DTCs must not be active. If a transmission IMS DTC
is active, the message "Engine running with transmission DTC present"
appears on the scan tool display. |
|
Shift Transmission
| --
|
• | When the ignition is ON, and the engine is OFF, there are no limits
to this control. The scan tool shift solenoid states change to match the Commanded
Gear selected. |
• | When the engine is running, the following control limits apply: |
- | The TCM does not allow a shift if it causes the engine RPM to exceed
a calibrated limit. If a gear is requested and the engine speed is too high, the
message "Engine speed too high" appears on the scan tool display. |
- | The TCM does not allow a 3-2 or 2-1 downshift if the
vehicle speed exceeds a calibrated limit. If either downshift is requested and
the vehicle speed is too high, the message "Eng. is on and veh. speed too
hi for 3-2 or 2-1 downshift" appears on the scan tool display. |
- | The TCM does not allow a 4-3 downshift if the vehicle speed
exceeds a calibrated limit. If a 4-3 downshift is requested and the vehicle
speed is too high, the message "Vehicle speed too high" appears on the
scan tool display. |
- | The TCM does not allow an upshift if the vehicle speed exceeds a calibrated
limit. If an upshift is requested and the vehicle speed is too high, the message "Vehicle
speed too high" appears on the scan tool display. |
- | The TCM does not allow an upshift that is greater than the current
selected transmission range. For example 3rd gear is not allowed if the transmission
range is D2. If an upshift is requested that is greater than the current selected
transmission range, the message "Eng. running and gear request is greater
than the current TR" appears on the scan tool display. |
|
TCC Control Solenoid
| --
|
• | The TCM commands the duty cycle of the TCC PWM solenoid. The
duty cycle is represented by a percentage of ON, energized, time. Approximately
90-100 percent duty cycle represents an ON, energized, commanded state.
Zero percent represents an OFF, non-energized, commanded state. The scan
tool TCC Duty Cycle parameter should match the commanded state. |
• | When the ignition is ON, and the engine is OFF, there are no limits
to this control. The solenoid remains ON, 90-100 percent duty cycle
until commanded OFF, zero percent duty cycle, and vice versa. When the output control
is exited, the solenoid duty cycle is determined by the TCM. |
• | When the engine is running, the following control limits apply: |
- | If the transmission range is Park, and the transmission is in hot mode,
the TCC control solenoid may not be commanded OFF. If the solenoid is requested
OFF, the message "TCC OFF command disabled in Hot Mode" appears on
the scan tool display. |
- | The TCC control solenoid may not be commanded OFF for more than a calibrated
amount of time. If the solenoid is commanded OFF, for a certain amount of time,
the message "TCC OFF time has been exceeded" appears on the scan tool
display. |
|
High Side Driver 1
| |
• | The TCM commands the driver for the solenoid voltage supply ON and
OFF. |
• | When the ignition is ON, and the engine is OFF, there are no limits
to this control. |
• | High side driver 1 may not be commanded ON and OFF with the
scan tool if the engine is running. |
|
High Side Driver 2
| --
|
• | The TCM commands the driver for the solenoid voltage supply ON and
OFF. |
• | When the ignition is ON, and the engine is OFF, there are no limits
to this control. |
• | High side driver 2 may not be commanded ON and OFF with the
scan tool if the engine is running. |
|