The camshaft position (CMP) actuator system is comprised of four CMP actuator solenoids, four oil control valves, and four CMP actuators. The engine control module (ECM) sends an electrical signal through the control circuits to the CMP actuator solenoids when a cam timing change is desired. The ground circuits of the CMP actuator solenoids are used as a return. If the ECM detects low voltage condition on one of these circuits, DTC P2088, P2090, P2092, P2094 sets.
• | DTCs P0010, P0013, P0020, P0023, P2088, P2089, P2090, P2091, P2092, P2093, P2094, P2095 are not set. |
• | The engine is running. |
• | The CMP actuator has been commanded for more than 1 second. |
• | The ignition voltage is between 11-26 volts. |
• | The ECM detects a low voltage condition on a CMP actuator solenoid control circuit. |
• | The above condition is met for more than 1.6 seconds. |
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
The CMP actuator system will be disabled until the end of the ignition cycle.
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Engine Controls Schematics Connector End View Reference: Engine Control Module Connector End Views or Engine Controls Connector End Views | |||
1 | Did you perform the Diagnostic System Check-Engine Controls? | Go to Step 2 | |
2 |
Did the DTC fail this ignition? | Go to Step 3 | Go to Intermittent Conditions |
3 |
Important: The scan tool will command the intake camshaft position (CMP) actuators as a set, and the exhaust CMP actuators as a set. Important: The CMP actuator output function will automatically raise the engine speed.
Did the test lamp illuminate when commanded with a scan tool? | Go to Step 5 | Go to Step 4 |
4 | Test the control circuit of the affected CMP actuator solenoid for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 6 |
5 | Test for shorted terminals at the affected CMP actuator solenoid. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 7 |
6 | Test for shorted terminals at the engine control module (ECM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 8 |
7 | Replace the affected CMP actuator solenoid. Refer to Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake , Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Exhaust , Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 2 (Left Side) Intake or Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 2 (Left Side) Exhaust . Did you complete the replacement? | Go to Step 9 | -- |
8 | Replace the ECM. Refer to Engine Control Module Replacement . Did you complete the replacement? | Go to Step 9 | -- |
9 |
Did the DTC fail this ignition? | Go to Step 3 | Go to Step 10 |
10 | Observe the Capture Info with a scan tool. Are there any DTCs that have not been diagnosed? | System OK |