Generator Bracket Replacement LH2

Removal Procedure


    Object Number: 887717  Size: SH
  1. Disconnect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection .
  2. Remove the generator. Refer to Generator Replacement .
  3. Remove the generator drive belt tensioner. Refer to Drive Belt Tensioner Replacement - Generator .
  4. Remove the right side engine mount bracket. Refer to Engine Mount Bracket Replacement - Right Side .
  5. Remove the generator bracket bolts (1, 2 and 3).
  6. Remove the generator bracket from the engine.

Installation Procedure


    Object Number: 887717  Size: SH
  1. Install the generator bracket to the engine.
  2. Notice: Refer to Fastener Notice in the Preface section.

  3. Install the generator bracket bolts.
  4. Tighten
    Tighten the generator bracket bolts in the sequence shown to 50 N·m (37 lb ft).

  5. Install the right side engine mount bracket. Refer to Engine Mount Bracket Replacement - Right Side .
  6. Install the generator drive belt tensioner. Refer to Drive Belt Tensioner Replacement - Generator .
  7. Install the generator. Refer to Generator Replacement .
  8. Connect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection .

Generator Bracket Replacement LY7

Removal Procedure

  1. Turn the ignition OFF.
  2. Remove the generator. Refer to Generator Replacement .
  3. Remove the coolant inlet pipe lower bolt from the generator bracket.
  4. Remove the belt tensioner. Refer to Water Pump and Generator Belt Tensioner Replacement .

  5. Object Number: 887707  Size: SH
  6. Remove the generator bracket bolts.
  7. Remove the generator bracket.

Installation Procedure


    Object Number: 887707  Size: SH
  1. Install the generator bracket.
  2. Notice: Refer to Fastener Notice in the Preface section.

  3. Install the generator bracket bolts.
  4. Tighten
    Tighten the generator bracket bolts in the sequence shown.

    2.1. Tighten the generator bracket bolts (1) to 50 N·m (37 lb in).
    2.2. Tighten the generator bracket bolts (2) to 50 N·m (37 lb in).
    2.3. Tighten the generator bracket bolt (3) to 23 N·m (17 lb in).
  5. Install the belt tensioner. Refer to Water Pump and Generator Belt Tensioner Replacement .
  6. Install the coolant inlet pipe lower bolt from the generator bracket.