Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Outside Mirrors System Check? | -- | Go to Step 2 | |||||
2 |
Is the voltage within the specified range? | 10-15 V | Go to Step 7 | Go to Step 3 | ||||
3 |
Did you find and correct the condition. | -- | Go to Step 4 | |||||
4 | Test CKT 267 (ORN) for an open. Is the circuit OK? | -- | Go to Step 6 | Go to Step 5 | ||||
5 | Repair the open in CKT 267 (ORN). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |||||
6 | Repair the open in one of the following circuits.
Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||
7 | Replace the inoperative outside mirror face. Refer to Mirror Face Replacement - Outside Electrochromatic . Did you complete the repair? | -- | -- |