Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Windows System Check? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified range? | 10-15 V | Go to Step 3 | Go to Step 4 |
3 | Use a DMM in order to backprobe the LH window switch between connector terminal H (PNK) and terminal G (BLK). Is the voltage within the specified range? | 10-15 V | Go to Step 5 | Go to Step 6 |
4 | Repair the open or short to ground in CKT 70 (PNK). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
5 | Replace the LH window switch. Refer to Front Side Door Window Switch Replacement . Did you complete the repair? | -- | -- | |
6 | Repair the open in CKT 50 (BLK). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- |