Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Remote Keyless Entry Diagnostic System Check? | -- | ||
2 | Is the remote keyless entry system inoperative from both transmitters? | -- | Go to Step 3 | Go to Step 4 |
3 | Reprogram the transmitters. Refer to Transmitter Programming Do the transmitters now work? | -- | Go to Step 5 | |
4 |
Does the transmitter work? | -- | Go to Step 10 | |
5 |
Is the voltage within the specified range? | 10 -15 V | Go to Step 7 | Go to Step 6 |
6 | Repair the open or short to ground in CKT 2640 (ORN). Refer to Wiring Repairs Is the repair complete? | -- | -- | |
7 | Measure the voltage between RFA module connector terminals 1 and 4. Is the voltage within the specified range? | 10 -15 V | Go to Step 9 | Go to Step 8 |
8 | Repair the open in CKT 1051 (BLK). Refer to Wiring Repairs Is the repair complete? | -- | -- | |
9 | Replace the RFA module. Refer to RFA Module Replacement Is the repair complete? | -- | -- | |
10 | Replace the transmitter. Refer to Transmitter Replacement Is the repair complete? | -- | -- |