Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Measure the voltage to ground from the IP compartment lamp connector terminal A (ORN). Is battery voltage measured? | -- | Go to Step 3 | Go to Step 5 |
3 | Measure the voltage from the IP compartment lamp connector terminal A (ORN) to terminal B (BLK). Is battery voltage measured? | -- | Go to Step 4 | Go to Step 6 |
4 | Replace the IP compartment lamp. Refer to Instrument Panel Compartment Lamp Switch Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- | Go to Step 7
| -- |
5 | Repair the open in CKT 640 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 7 | -- |
6 | Repair the open in CKT 150 (BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK. | Go to Step 2 |