Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the entire Interior Lights Dimming System Check? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified range? | 10-15 V | Go to Step 3 | Go to Step 5 |
3 | Connect a DMM from the instrument cluster connector C1 cavity A4 (LT GRN) to ground. Is the voltage within the specified range? | 10-15 V | Go to Step 4 | Go to Step 6 |
4 | Replace the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console. Is the instrument cluster replacement complete? | -- | -- | |
5 | Repair the open in CKT 1039 (PNK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Repair the open in CKT 147 (LT GRN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |