Tools Required
J 22124-B J 22124-B
Pressure Gage (0-300 psi)
- Disconnect the air tube from the air dryer.
- Attach the J 22124-B
J 22124-B adapter tube to the air dryer.
- Attach the J 22124-B
J 22124-B gage to the J 22124-B
J 22124-B adapter tube with the toggle valve (5) on the
opposite side from the air compressor. Close the toggle valve.
- Apply air pressure at the schrader valve (4). Pressurize until
the J 22124-B
J 22124-B
reads 690 kPa (100 psi).
- Check the following areas using soap bubbles:
• | Solenoid valve (1) -- Replace the air compressor head if
leaking. |
• | Air dryer to compressor head O-ring (2) -- Replace the air
dryer if leaking. |
• | Air dryer cover (3) -- Replace the air dryer if leaking. |
• | Air compressor head gasket (6) -- Replace the air compressor
head if leaking. |
• | Air compressor head cover gasket (7) -- Tighten the cover
bolts to 5.6 N·m (50 lb. in.) if the head cover
gasket is leaking. If the leak persists, replace the air compressor head. |